volume 13 issue 8 pages 722-726

The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model

Andreas M. Frölich 1, 2
Warren Kim 3, 4
Knut Stribrny 1, 2
Olav Jansen 5, 6
Markus Möhlenbruch 7, 8
István Szikora 9, 10
Fritz Wodarg 5, 11
Jens Fiehler 2, 12
Kim Otto 13
Tony Chou 13
Jan-Hendrik Buhk 1, 2
Joey English 3, 4
1
 
Department of Diagnostic and Interventional Neuroradiology
3
 
Radiology
5
 
Department of Radiology and Neuroradiology
7
 
Neuroradiology
9
 
Neurointerventions
10
 
National Institute of Neurosciences
12
 
Department of Neuroradiology
13
 
Route Medical, Inc
Publication typeJournal Article
Publication date2020-09-03
scimago Q1
wos Q1
SJR1.634
CiteScore8.8
Impact factor4.3
ISSN17598478, 17598486
General Medicine
Surgery
Neurology (clinical)
Abstract
Background

In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience.

Methods

In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7.

Results

In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%).

Conclusion

Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model’s observations.

Found 
Found 

Top-30

Journals

1
2
3
4
5
6
Journal of NeuroInterventional Surgery
6 publications, 26.09%
Interventional Neuroradiology
5 publications, 21.74%
Stroke Vascular and Interventional Neurology
4 publications, 17.39%
Neurointervention
2 publications, 8.7%
Frontiers in Medical Technology
1 publication, 4.35%
Clinical Neurology and Neurosurgery
1 publication, 4.35%
Stroke
1 publication, 4.35%
Neurosurgery Open
1 publication, 4.35%
1
2
3
4
5
6

Publishers

1
2
3
4
5
6
BMJ
6 publications, 26.09%
Ovid Technologies (Wolters Kluwer Health)
6 publications, 26.09%
SAGE
5 publications, 21.74%
Korean Society of Interventional Neuroradiology
2 publications, 8.7%
Frontiers Media S.A.
1 publication, 4.35%
Elsevier
1 publication, 4.35%
Cold Spring Harbor Laboratory
1 publication, 4.35%
Springer Nature
1 publication, 4.35%
1
2
3
4
5
6
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
23
Share
Cite this
GOST |
Cite this
GOST Copy
Frölich A. M. et al. The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model // Journal of NeuroInterventional Surgery. 2020. Vol. 13. No. 8. pp. 722-726.
GOST all authors (up to 50) Copy
Frölich A. M., Kim W., Stribrny K., Jansen O., Möhlenbruch M., Szikora I., Wodarg F., Fiehler J., Otto K., Chou T., Buhk J., English J. The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model // Journal of NeuroInterventional Surgery. 2020. Vol. 13. No. 8. pp. 722-726.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1136/neurintsurg-2020-016412
UR - https://doi.org/10.1136/neurintsurg-2020-016412
TI - The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model
T2 - Journal of NeuroInterventional Surgery
AU - Frölich, Andreas M.
AU - Kim, Warren
AU - Stribrny, Knut
AU - Jansen, Olav
AU - Möhlenbruch, Markus
AU - Szikora, István
AU - Wodarg, Fritz
AU - Fiehler, Jens
AU - Otto, Kim
AU - Chou, Tony
AU - Buhk, Jan-Hendrik
AU - English, Joey
PY - 2020
DA - 2020/09/03
PB - BMJ
SP - 722-726
IS - 8
VL - 13
PMID - 32883781
SN - 1759-8478
SN - 1759-8486
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2020_Frölich,
author = {Andreas M. Frölich and Warren Kim and Knut Stribrny and Olav Jansen and Markus Möhlenbruch and István Szikora and Fritz Wodarg and Jens Fiehler and Kim Otto and Tony Chou and Jan-Hendrik Buhk and Joey English},
title = {The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model},
journal = {Journal of NeuroInterventional Surgery},
year = {2020},
volume = {13},
publisher = {BMJ},
month = {sep},
url = {https://doi.org/10.1136/neurintsurg-2020-016412},
number = {8},
pages = {722--726},
doi = {10.1136/neurintsurg-2020-016412}
}
MLA
Cite this
MLA Copy
Frölich, Andreas M., et al. “The novel Tenzing 7 delivery catheter designed to deliver intermediate catheters to the face of embolus without crossing: clinical performance predicted in anatomically challenging model.” Journal of NeuroInterventional Surgery, vol. 13, no. 8, Sep. 2020, pp. 722-726. https://doi.org/10.1136/neurintsurg-2020-016412.