International Journal of Molecular Imaging, volume 2016, pages 1-11

Understanding Lung Deposition of Alpha-1 Antitrypsin in Acute Experimental Mouse Lung Injury Model Using Fluorescence Microscopy

Mengmeng Wang 1
Yutian Zhan 2
Chen Jianqing 3
Haojing Rong 1
Shawn P O'Neil 2
Brahma Ghosh 4
Vuong Nguyen 2
Jane Owens 5
Xianfeng Li 5
Denise O’Hara 1
Show full list: 10 authors
1
 
Pharmacokinetics, Dynamics and Metabolism, Pfizer Inc., Andover, MA, USA
2
 
Drug Safety R&D, Pfizer Inc., Andover, MA, USA
3
 
Clinical R&D, Pfizer Inc., Cambridge, MA, USA
4
 
Molecular Imaging Laboratory, Pfizer Inc., Andover, MA, USA
5
 
Rare Disease RU, Pfizer Inc., Cambridge, MA, USA
Publication typeJournal Article
Publication date2016-12-06
SJR
CiteScore
Impact factor
ISSN20901712, 20901720
Radiology, Nuclear Medicine and imaging
Abstract

Human plasma-derived α1-antitrypsin (AAT) delivered by intravenous infusion is used as augmentation therapy in patients with emphysema who have a genetic mutation resulting in deficiency of AAT. Inhalation is an alternative route of administration that can potentially increase the efficacy and convenience of treatment. This study was conducted to determine whether delivery to the lungs, initially via the intratracheal (IT) route of administration, would deliver efficacious levels of a recombinant AAT (rAAT) to the site of action in the lungs in mice. 125I-radiolabeled rAAT, fluorophore-conjugated rAAT (rAAT-Alexa488), and NE680 (neutrophil elastase 680, a silent fluorescent substrate of neutrophil elastase which fluoresces in the near-infrared range upon activation by neutrophil elastase) were used to characterize the pharmacokinetics and tissue distribution profile, distribution of rAAT within the lung, and efficacy of rAAT to inhibit neutrophil elastase at the site of action, respectively. The study has demonstrated that rAAT was able to gain access to locations where neutrophil elastase was localized. The histochemical quantification of rAAT activity relative to dose at the site of action provided here will improve confidence in predicting the human dose via the inhalation route.

Found 
Found 

Top-30

Journals

1
1

Publishers

1
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?