Open Access
Open access
International Journal of Analytical Chemistry, volume 2024, pages 1-9

Development of a Novel Multiplex PCR Method for the Rapid Detection of SARS-CoV-2, Influenza A Virus, and Influenza B Virus

Liang Ma 1
Haoyan Zhu 1
Yong-Wei Jiang 1
Xiao-Mu Kong 1
Peng Gao 1
Yi Liu 1
Meimei Zhao 1
Guoxiong Deng 1
Yongtong Cao 1
Show full list: 9 authors
Publication typeJournal Article
Publication date2024-02-29
scimago Q3
wos Q3
SJR0.314
CiteScore3.1
Impact factor1.5
ISSN16878760, 16878779
Analytical Chemistry
Abstract

Objective. A sensitive and specific multiplex fluorescence rapid detection method was established for simultaneous detection of SARS-CoV-2, influenza A virus, and influenza B virus in a self-made device within 30 min, with a minimum detection limit of 200 copies/mL. Methods. Based on the genome sequences of SARS-CoV-2, influenza A virus (FluA), and influenza B virus (FluB) with reference to the Chinese Center for Disease Control and Prevention and related literature, specific primers were designed, and a multiplex fluorescent PCR system was established. The simultaneous and rapid detection of SARS-CoV-2, FluA, and FluB was achieved by optimizing the concentrations of Taq DNA polymerase as well as primers, probes, and Mg2+. The minimum detection limits of the nucleic acid rapid detection system for SARS-CoV-2, FluA, and FluB were evaluated. Results. By optimizing the amplification system, the N enzyme with the best amplification performance was selected, and the optimal concentration of Mg2+ in the multiamplification system was 3 mmol/L; the final concentrations of SARS-CoV-2 NP probe and primer were 0.15 μmol/L and 0.2 μmol/L, respectively; the final concentrations of SARS-CoV-2 ORF probe and primer were both 0.15 μmol/L; the final concentrations of FluA probe and primer were 0.2 μmol/L and 0.3 μmol/L, respectively; the final concentrations of FluB probe and primer were 0.15 μmol/L and 0.25 μmol/L, respectively. Conclusion. A multiplex real-time quantitative fluorescence RT-PCR system for three respiratory viruses of SARS-CoV-2, FluA, and FluB was established with a high amplification efficiency and sensitivity reaching 200 copies/mL for all samples. Combined with the automated microfluidic nucleic acid detection system, the system can achieve rapid detection in 30 minutes.

Found 
Found 

Top-30

Journals

1
1

Publishers

1
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?