Open Access
Open access
Journal of Combustion, volume 2022, pages 1-11

Effectiveness of Charcoal Adsorbent in Flue Gas Filters for PCB Reduction in Smoke from Hospital Incinerators

Robert Ohene Adu 1
Samuel F Gyasi 2, 3
David Kofi Essumang 4
1
 
Department of Civil and Environmental Engineering, University of Energy and Natural Resources, Sunyani, BA, Ghana
2
 
Department of Biological Science, University of Energy and Natural Resources, Sunyani, BA, Ghana
3
 
Center for Research in Applied Biology, CeRAB, University of Energy and Natural Resources, Sunyani, BA, Ghana
Publication typeJournal Article
Publication date2022-09-30
scimago Q3
SJR0.210
CiteScore2.0
Impact factor1.5
ISSN20901968, 20901976
General Chemical Engineering
Condensed Matter Physics
Energy Engineering and Power Technology
Fuel Technology
Abstract

The release of gas-phase polychlorinated biphenyls (PCBs) as one of the persistent organic pollutants (POPs) is an unfortunate result of combustion, especially from medical waste incinerators. This tends to make incinerators unpopular. The idea of a cheaply available air pollution control device fitted to incinerator chimneys can justify the continued use of incinerators. A gas filter unit, consisting of 3 filter beds with activated charcoal as an adsorbent, was designed, constructed, and fitted onto an existing incinerator at a university hospital in Ghana. Flue gas from the incinerator was sampled before and after the filter beds, using cylindrically-shaped mini-polyurethane foam (mini-PUF) samplers, and the analytes in the samples were then Soxhlet-extracted, purified, and analyzed for certain PCBs using the gas chromatography-mass spectrometer (GC-MS) technique. Twelve of the 14 indicators PCBs analyzed in the smoke samples were present, and 11 of them saw mean reductions ranging from 3.67% to 54.9% by the charcoal filter beds. These were PCB 18, PCB 28, PCB 31, PCB 44, PCB 101, PCB 118, PCB 138, PCB149, PCB 153, PCB 170, and PCB180. The gaseous concentrations of PCBs before filtration ranged from 0.0000788 ng/m3 for PCB 180 to 0.00129 ng/m3 for PCB 153. After the filtration by the charcoal adsorbent, they ranged from 0.00003734 ng/m3 for PCB 170 to 0.00112016 ng/m3 for PCB 153. The highest mean reduction of 54.9% came from the homologue, PCB 180, whilst the homologue with a dioxin-like character (PCB 118) saw a 22.44% reduction. This suggests that dioxins and other dioxin-like compounds are most likely adsorbed by the charcoal adsorbent. This gas filter unit should further be investigated for its effectiveness at removing other dioxin-like PCBs, dioxins, and furanes and for testing the effectiveness of thermophilic bacterial strains that can further metabolize these POPs into less harmful products.

Found 
Found 

Top-30

Journals

1
1

Publishers

1
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?