Open Access
Open access
том 26 страницы 107602962094684

Is There a “Blind Spot” in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study

Тип публикацииJournal Article
Дата публикации2020-01-01
scimago Q2
wos Q3
БС2
SJR0.635
CiteScore4.0
Impact factor2.0
ISSN10760296, 19382723
General Medicine
Hematology
Краткое описание

Identifying the cause of a bleeding complication after cardiac surgery can be crucial. This study sought to clarify whether the application of unprocessed autologous pump blood influences anti-factor Xa activity after cardiac surgery and evaluated 2 point-of-care methods regarding their ability to identify an elevated anti-factor Xa activity at different timepoints after cardiopulmonary bypass. Anti-factor Xa activity, heparin/protamine titration and the clotting time ratio of thromboelastometry in the INTEM and HEPTEM were measured at baseline (T1), after the application of protamine (T2) and after the complete application of autologous pump blood (T3). Anti-factor Xa activity decreased significantly between T2 and T3 as well did the absolute number of patients with an elevated anti-factor Xa activity. Receiver Operating Curve analyses were performed for both point-of-care methods. At T2 neither could identify patients with an elevated anti-factor Xa activity, while both methods were able to do so at T3 with high sensitivity and specificity. This difference suggests that an interference in the detection of residual heparinization with point-of-care methods exists right after the application of protamine, which seems to subside after a short time span. Nevertheless, results of point-of-care testing for residual heparinization after cardiopulmonary bypass need to be interpreted considering the protamine-heparin ratio and the timepoint of protamine administration.

Найдено 
Найдено 

Топ-30

Журналы

1
Journal of Cardiothoracic and Vascular Anesthesia
1 публикация, 14.29%
BJA Education
1 публикация, 14.29%
Veterinary and Comparative Orthopaedics and Traumatology
1 публикация, 14.29%
Perfusion (United Kingdom)
1 публикация, 14.29%
Journal of Cardiac Critical Care TSS
1 публикация, 14.29%
Japanese Journal of Extra-Corporeal Technology
1 публикация, 14.29%
European Journal of Anaesthesiology
1 публикация, 14.29%
1

Издатели

1
2
Elsevier
2 публикации, 28.57%
Georg Thieme Verlag KG
1 публикация, 14.29%
SAGE
1 публикация, 14.29%
Scientific Scholar
1 публикация, 14.29%
The Japanese Society of Extra-Corporeal Technology in Medicine
1 публикация, 14.29%
Ovid Technologies (Wolters Kluwer Health)
1 публикация, 14.29%
1
2
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
7
Поделиться
Цитировать
ГОСТ |
Цитировать
Wand S. et al. Is There a “Blind Spot” in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study // Clinical and Applied Thrombosis/Hemostasis. 2020. Vol. 26. p. 107602962094684.
ГОСТ со всеми авторами (до 50) Скопировать
Wand S., Heise D., Hillmann N., Bireta C., Bräuer A., Ahsen N. V., Quintel M. Is There a “Blind Spot” in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study // Clinical and Applied Thrombosis/Hemostasis. 2020. Vol. 26. p. 107602962094684.
RIS |
Цитировать
TY - JOUR
DO - 10.1177/1076029620946843
UR - https://doi.org/10.1177/1076029620946843
TI - Is There a “Blind Spot” in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study
T2 - Clinical and Applied Thrombosis/Hemostasis
AU - Wand, Saskia
AU - Heise, Daniel
AU - Hillmann, Nadine
AU - Bireta, Christian
AU - Bräuer, Anselm
AU - Ahsen, Nicolas von
AU - Quintel, Michael
PY - 2020
DA - 2020/01/01
PB - SAGE
SP - 107602962094684
VL - 26
PMID - 32795187
SN - 1076-0296
SN - 1938-2723
ER -
BibTex
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2020_Wand,
author = {Saskia Wand and Daniel Heise and Nadine Hillmann and Christian Bireta and Anselm Bräuer and Nicolas von Ahsen and Michael Quintel},
title = {Is There a “Blind Spot” in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study},
journal = {Clinical and Applied Thrombosis/Hemostasis},
year = {2020},
volume = {26},
publisher = {SAGE},
month = {jan},
url = {https://doi.org/10.1177/1076029620946843},
pages = {107602962094684},
doi = {10.1177/1076029620946843}
}