BMC Cardiovascular Disorders, volume 13, issue 1, publication number 15

Measurement of the ankle brachial index with a non-mercury sphygmomanometer in diabetic patients: a concordance study

Magdalena Bundó 1
Magalí Urrea 2
Laura Muñoz Ortiz 2
Carmen Pérez 3
Judit Llussà 4
Rosa Forés 5
Maria Teresa Alzamora 5
Pere Torán 2, 6
1
 
Primary Health Care Centre Ronda Prim, Catalan Health Institute, Mataró, Barcelona, Spain
3
 
Primary Health Care Centre Llefià, Catalan Health Institute, Badalona, Spain
4
 
Primary Health Care Centre Sant Roc, Catalan Health Institute, Badalona, Spain
5
 
Primary Health Care Centre Riu Nord-Riu Sud, Catalan Health Institute, Barcelona, Spain
6
 
Primary Health Care Centre Gatassa, Catalan Health Institute, Mataró, Spain
Publication typeJournal Article
Publication date2013-03-08
scimago Q2
SJR0.646
CiteScore3.5
Impact factor2
ISSN14712261
Cardiology and Cardiovascular Medicine
Abstract
The removal of mercury sphygmomanometers from health centers requires the validation of other instruments to measure blood pressure in the limbs to calculate the ankle-brachial index (ABI). Descriptive cross-sectional study of agreement between two measurement methods in type 2 diabetes patients from three urban primary healthcare centres in the Barcelonès Nord i Maresme area (Catalonia, Spain). ABI was determined with Doppler and mercury sphygmomanometer and Doppler and the “hybrid” sphygmomanometer OMRON HEM-907 model. Agreement was evaluated using the weighted kappa index. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using the mercury sphygmomanometer as the gold standard. 211 patients were included, from these, 421 limbs were available for study. The mean age of the participants was 67 years (SD = 10), 51.7% were women. The index of agreement between ABI measured with a mercury sphygmomanometer and with the OMRON HEM-907 blood pressure monitor was good (weighted kappa index = 0.68; CI 95%: [0.55–0.79]) and improved when the ABI cut-off value was set at ≤0.70 (weighted kappa index = 0.92; CI 95%: [0.81–1.00]). Sensitivity and specificity were 77.5% and 98.2%, respectively. PPV was 83.8% and NPV was 97.3%. With the ABI cut-off value ≤0.70, sensitivity and specificity increased to 85.7% and 100%, respectively, PPV to 100% and NPV to 99.4%. The combination of a Doppler device with the hybrid sphygmomanometer is a simple and reliable method to measure ABI showing that hybrid sphygmomanometer is a good alternative to the use of mercury sphygmomanometers.
Found 
Found 

Top-30

Journals

1
1

Publishers

1
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?