Abstract
Background

The accuracy of intraoral scanning plays a crucial role in the workflow of computer-assisted design/computer-assisted manufacturing. However, data regarding scanning accuracy for inlay preparation designs are lacking. The purpose of this in vitro study was to evaluate the influence of the depth of the occlusal cavity and width of the gingival floor of the proximal box on the trueness and precision of intraoral scans for inlay restoration.

Methods

Artificial teeth were used in this study. Four types of preparations for mesio-occlusal inlay were performed on each #36 artificial tooth depending on two different depths of the occlusal cavity (1 mm and 2 mm) and widths of the gingival floor of the proximal box (1.5 mm and 2.5 mm). Artificial teeth were scanned 10 times each with Cerec Primescan AC, and another scan was performed subsequently with a laboratory scanner as a reference (n = 10). Standard tessellation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using two-way analysis of variance and the Bonferroni multiple comparison test.

Results

The narrow shallow group had significantly higher deviation values for trueness than the wide deep group (p < 0.05). The wide deep group had the lowest average deviation value for trueness and there was no significant difference between the narrow deep and wide shallow groups (p > 0.05). For the mean maximum positive deviation, the wide groups had significantly lower values than the narrow groups (p < 0.05). Trueness was affected by both the width and depth(p < 0.05), whereas the mean maximum positive deviation was affected by the width (p < 0.05). The mean maximum negative deviation was affected by all three factors (p < 0.05). Precision was affected by the depth and the interaction between the depth of the occlusal cavity and width of the gingival floor (p < 0.05).

Conclusions

The design of different inlay cavity configurations affected the accuracy of the digital intraoral scanner. The highest average deviation for trueness was observed in the narrow shallow group and the lowest in the wide deep group. With regard to precision, the narrow shallow group showed the lowest average deviation, and the narrow deep group showed highest value.

Found 
Found 

Top-30

Journals

1
2
Journal of Dentistry
2 publications, 14.29%
BMC Oral Health
2 publications, 14.29%
Journal of Esthetic and Restorative Dentistry
2 publications, 14.29%
Journal of Clinical Medicine
2 publications, 14.29%
Scientific Reports
2 publications, 14.29%
Heliyon
1 publication, 7.14%
Clinical Oral Investigations
1 publication, 7.14%
Journal of Prosthetic Dentistry
1 publication, 7.14%
Applied Sciences (Switzerland)
1 publication, 7.14%
1
2

Publishers

1
2
3
4
5
Springer Nature
5 publications, 35.71%
Elsevier
4 publications, 28.57%
MDPI
3 publications, 21.43%
Wiley
2 publications, 14.29%
1
2
3
4
5
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
14
Share
Cite this
GOST |
Cite this
GOST Copy
Park Y. et al. Scanning accuracy of an intraoral scanner according to different inlay preparation designs // BMC Oral Health. 2023. Vol. 23. No. 1. 515
GOST all authors (up to 50) Copy
Park Y., Kim J. H., Park J. K., Son S. Scanning accuracy of an intraoral scanner according to different inlay preparation designs // BMC Oral Health. 2023. Vol. 23. No. 1. 515
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1186/s12903-023-03233-2
UR - https://doi.org/10.1186/s12903-023-03233-2
TI - Scanning accuracy of an intraoral scanner according to different inlay preparation designs
T2 - BMC Oral Health
AU - Park, Yeri
AU - Kim, Jae Hoon
AU - Park, Jeong Kil
AU - Son, Sung-Ae
PY - 2023
DA - 2023/07/24
PB - Springer Nature
IS - 1
VL - 23
PMID - 37488581
SN - 1472-6831
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2023_Park,
author = {Yeri Park and Jae Hoon Kim and Jeong Kil Park and Sung-Ae Son},
title = {Scanning accuracy of an intraoral scanner according to different inlay preparation designs},
journal = {BMC Oral Health},
year = {2023},
volume = {23},
publisher = {Springer Nature},
month = {jul},
url = {https://doi.org/10.1186/s12903-023-03233-2},
number = {1},
pages = {515},
doi = {10.1186/s12903-023-03233-2}
}