Open Access
MRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study
Joshua Shur
1
,
Matthew Blackledge
2
,
James d’Arcy
2
,
David J. Collins
2
,
Maria Bali
1
,
Martin Oleach
2
,
Dow-Mu Koh
1, 2
1
Department of Radiology, the Royal Marsden NHS Foundation Trust, London, UK
|
2
CRUK Cancer Imaging Centre, The Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, London, UK
|
Тип публикации: Journal Article
Дата публикации: 2021-01-19
scimago Q1
wos Q1
БС1
SJR: 0.941
CiteScore: 4.8
Impact factor: 3.6
ISSN: 25099280
PubMed ID:
33462642
Radiology, Nuclear Medicine and imaging
Краткое описание
To evaluate robustness and repeatability of magnetic resonance imaging (MRI) texture features in water and tissue phantom test-retest study. Separate water and tissue phantoms were imaged twice with the same protocol in a test-retest experiment using a 1.5-T scanner. Protocols were acquired to favour signal-to-noise ratio and resolution. Forty-six features including first order statistics and second-order texture features were extracted, and repeatability was assessed by calculating the concordance correlation coefficient. Separately, base image noise and resolution were manipulated in an in silico experiment, and robustness of features was calculated by assessing percentage coefficient of variation and linear correlation of features with noise and resolution. These simulation data were compared with the acquired data. Features were classified by their degree (high, intermediate, or low) of robustness and repeatability. Eighty percent of the MRI features were repeatable (concordance correlation coefficient > 0.9) in the phantom test-retest experiment. The majority (approximately 90%) demonstrated a strong or intermediate correlation with image acquisition parameter, and 19/46 (41%) and 13/46 (28%) of features were highly robust to noise and resolution, respectively (coefficient of variation < 5%). Agreement between the acquired and simulation data varied, with the range of agreement within feature classes between 11 and 92%. Most MRI features were repeatable in a phantom test-retest study. This phantom data may serve as a lower limit of feature MRI repeatability. Robustness of features varies with acquisition parameter, and appropriate features can be selected for clinical validation studies.
Найдено
Ничего не найдено, попробуйте изменить настройки фильтра.
Найдено
Ничего не найдено, попробуйте изменить настройки фильтра.
Топ-30
Журналы
|
1
2
3
|
|
|
Frontiers in Oncology
3 публикации, 13.04%
|
|
|
European radiology experimental
3 публикации, 13.04%
|
|
|
Cancers
2 публикации, 8.7%
|
|
|
Physics in Medicine and Biology
2 публикации, 8.7%
|
|
|
British Journal of Radiology
1 публикация, 4.35%
|
|
|
Journal of Personalized Medicine
1 публикация, 4.35%
|
|
|
Scientific Reports
1 публикация, 4.35%
|
|
|
Computers and Chemical Engineering
1 публикация, 4.35%
|
|
|
Journal of Magnetic Resonance Imaging
1 публикация, 4.35%
|
|
|
Digital Diagnostics
1 публикация, 4.35%
|
|
|
Journal of Medical Imaging and Radiation Sciences
1 публикация, 4.35%
|
|
|
Izmeritel`naya Tekhnika
1 публикация, 4.35%
|
|
|
Measurement Techniques
1 публикация, 4.35%
|
|
|
Thermal Science and Engineering Progress
1 публикация, 4.35%
|
|
|
Magnetic Resonance Materials in Physics, Biology, and Medicine
1 публикация, 4.35%
|
|
|
BMC Medical Imaging
1 публикация, 4.35%
|
|
|
1
2
3
|
Издатели
|
1
2
3
4
5
6
7
|
|
|
Springer Nature
7 публикаций, 30.43%
|
|
|
MDPI
3 публикации, 13.04%
|
|
|
Frontiers Media S.A.
3 публикации, 13.04%
|
|
|
Elsevier
3 публикации, 13.04%
|
|
|
IOP Publishing
2 публикации, 8.7%
|
|
|
British Institute of Radiology
1 публикация, 4.35%
|
|
|
Wiley
1 публикация, 4.35%
|
|
|
Eco-Vector LLC
1 публикация, 4.35%
|
|
|
FSUE VNIIMS All-Russian Research Institute of Metrological Service
1 публикация, 4.35%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
1 публикация, 4.35%
|
|
|
1
2
3
4
5
6
7
|
- Мы не учитываем публикации, у которых нет DOI.
- Статистика публикаций обновляется еженедельно.
Вы ученый?
Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
23
Всего цитирований:
23
Цитирований c 2024:
11
(47.82%)
Цитировать
ГОСТ |
RIS |
BibTex
Цитировать
ГОСТ
Скопировать
Shur J. et al. MRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study // European radiology experimental. 2021. Vol. 5. No. 1. 2
ГОСТ со всеми авторами (до 50)
Скопировать
Shur J., Blackledge M., d’Arcy J., Collins D. J., Bali M., Oleach M., Koh D. MRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study // European radiology experimental. 2021. Vol. 5. No. 1. 2
Цитировать
RIS
Скопировать
TY - JOUR
DO - 10.1186/s41747-020-00199-6
UR - https://doi.org/10.1186/s41747-020-00199-6
TI - MRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study
T2 - European radiology experimental
AU - Shur, Joshua
AU - Blackledge, Matthew
AU - d’Arcy, James
AU - Collins, David J.
AU - Bali, Maria
AU - Oleach, Martin
AU - Koh, Dow-Mu
PY - 2021
DA - 2021/01/19
PB - Springer Nature
IS - 1
VL - 5
PMID - 33462642
SN - 2509-9280
ER -
Цитировать
BibTex (до 50 авторов)
Скопировать
@article{2021_Shur,
author = {Joshua Shur and Matthew Blackledge and James d’Arcy and David J. Collins and Maria Bali and Martin Oleach and Dow-Mu Koh},
title = {MRI texture feature repeatability and image acquisition factor robustness, a phantom study and in silico study},
journal = {European radiology experimental},
year = {2021},
volume = {5},
publisher = {Springer Nature},
month = {jan},
url = {https://doi.org/10.1186/s41747-020-00199-6},
number = {1},
pages = {2},
doi = {10.1186/s41747-020-00199-6}
}