Open Access
Open access
volume 74 issue 1 pages 58

Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model

Publication typeJournal Article
Publication date2024-12-21
scimago Q2
wos Q2
SJR0.791
CiteScore4.2
Impact factor3.2
ISSN18806546, 18806562
Abstract

Fenestration has been reported to enhance Fontan hemodynamics in several cases of Fontan circulation. However, the indication criteria for fenestration remain under discussion. To assess the effectiveness of fenestration in Fontan circulation, we conducted a theoretical analysis using a computational model of the fenestrated Fontan circulation. The cardiac chambers and vascular systems were modeled using the time-varying elastance model and the modified Windkessel model, respectively. When the pulmonary vascular resistance index was 4.01 Wood units m2, fenestration significantly reduced central venous pressure from 18.0 to 16.1 mmHg and decreased stressed blood volume from 610 to 555 ml. However, in the models with reduced ventricular end-systolic elastance, increased ventricular stiffness constant, or heightened systemic vascular resistance, the advantages of fenestration were diminished. Thus, fenestration may effectively improve the hemodynamics of Fontan circulation in patients with elevated pulmonary vascular resistance.

Found 
Found 

Top-30

Journals

1
Expert Review of Cardiovascular Therapy
1 publication, 100%
1

Publishers

1
Taylor & Francis
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Horio N. et al. Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model // Journal of Physiological Sciences. 2024. Vol. 74. No. 1. p. 58.
GOST all authors (up to 50) Copy
Horio N., Shimizu S., Kotani Y., Miyahara Y., Kasahara S. Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model // Journal of Physiological Sciences. 2024. Vol. 74. No. 1. p. 58.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1186/s12576-024-00947-y
UR - https://jps.biomedcentral.com/articles/10.1186/s12576-024-00947-y
TI - Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model
T2 - Journal of Physiological Sciences
AU - Horio, Naohiro
AU - Shimizu, Shuji
AU - Kotani, Yasuhiro
AU - Miyahara, Yoshinori
AU - Kasahara, Shingo
PY - 2024
DA - 2024/12/21
PB - Elsevier
SP - 58
IS - 1
VL - 74
PMID - 39707201
SN - 1880-6546
SN - 1880-6562
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Horio,
author = {Naohiro Horio and Shuji Shimizu and Yasuhiro Kotani and Yoshinori Miyahara and Shingo Kasahara},
title = {Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model},
journal = {Journal of Physiological Sciences},
year = {2024},
volume = {74},
publisher = {Elsevier},
month = {dec},
url = {https://jps.biomedcentral.com/articles/10.1186/s12576-024-00947-y},
number = {1},
pages = {58},
doi = {10.1186/s12576-024-00947-y}
}
MLA
Cite this
MLA Copy
Horio, Naohiro, et al. “Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model.” Journal of Physiological Sciences, vol. 74, no. 1, Dec. 2024, p. 58. https://jps.biomedcentral.com/articles/10.1186/s12576-024-00947-y.