Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw
Evangelos Christodoulou
1
,
Suresh Chinthakunta
2
,
Divya Reddy
2
,
Saif Khalil
2
,
Thomas Apostolou
3
,
Philipp Drees
4
,
Konstantinos Kafchitsas
1
1
Asklepios Klinik Lindenlohe, Schwandorf, Germany
|
2
Globus Medical Inc., Audubon, USA
|
3
G. Papanikalaou Hospital Exohi, Thessaloniki, Greece
|
Publication type: Journal Article
Publication date: 2015-05-01
PubMed ID:
25949274
Orthopedics and Sports Medicine
Abstract
The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw. Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded. The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws. Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
|
|
|
Global Spine Journal
2 publications, 8.7%
|
|
|
Spine Deformity
2 publications, 8.7%
|
|
|
Advances in Materials and Processing Technologies
2 publications, 8.7%
|
|
|
Clinics in Orthopedic Surgery
2 publications, 8.7%
|
|
|
Revista Espanola de Cirugia Ortopedica y Traumatologia
2 publications, 8.7%
|
|
|
Clinical Biomechanics
1 publication, 4.35%
|
|
|
Spine Journal
1 publication, 4.35%
|
|
|
Orthopaedic surgery
1 publication, 4.35%
|
|
|
Journal of Korean Neurosurgical Society
1 publication, 4.35%
|
|
|
Asian Spine Journal
1 publication, 4.35%
|
|
|
Advanced Structured Materials
1 publication, 4.35%
|
|
|
Journal of Clinical Orthopaedics and Trauma
1 publication, 4.35%
|
|
|
Materials
1 publication, 4.35%
|
|
|
Die Wirbelsäule
1 publication, 4.35%
|
|
|
The Journal of the Korean Orthopaedic Association
1 publication, 4.35%
|
|
|
Coatings
1 publication, 4.35%
|
|
|
Biomedical Materials & Devices
1 publication, 4.35%
|
|
|
Journal of Spine Surgery
1 publication, 4.35%
|
|
|
1
2
|
Publishers
|
1
2
3
4
5
6
|
|
|
Elsevier
6 publications, 26.09%
|
|
|
Springer Nature
3 publications, 13.04%
|
|
|
SAGE
2 publications, 8.7%
|
|
|
Taylor & Francis
2 publications, 8.7%
|
|
|
Korean Orthopaedic Association
2 publications, 8.7%
|
|
|
MDPI
2 publications, 8.7%
|
|
|
Wiley
1 publication, 4.35%
|
|
|
Daehan sin'gyeong oe'gwa haghoe
1 publication, 4.35%
|
|
|
Korean Society of Spine Surgery
1 publication, 4.35%
|
|
|
Georg Thieme Verlag KG
1 publication, 4.35%
|
|
|
XMLink
1 publication, 4.35%
|
|
|
AME Publishing Company
1 publication, 4.35%
|
|
|
1
2
3
4
5
6
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
23
Total citations:
23
Citations from 2024:
6
(26.09%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Christodoulou E. et al. Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw // Scoliosis. 2015. Vol. 10. No. 1. 15
GOST all authors (up to 50)
Copy
Christodoulou E., Chinthakunta S., Reddy D., Khalil S., Apostolou T., Drees P., Kafchitsas K. Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw // Scoliosis. 2015. Vol. 10. No. 1. 15
Cite this
RIS
Copy
TY - JOUR
DO - 10.1186/s13013-015-0039-6
UR - https://doi.org/10.1186/s13013-015-0039-6
TI - Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw
T2 - Scoliosis
AU - Christodoulou, Evangelos
AU - Chinthakunta, Suresh
AU - Reddy, Divya
AU - Khalil, Saif
AU - Apostolou, Thomas
AU - Drees, Philipp
AU - Kafchitsas, Konstantinos
PY - 2015
DA - 2015/05/01
PB - Springer Nature
IS - 1
VL - 10
PMID - 25949274
SN - 1748-7161
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2015_Christodoulou,
author = {Evangelos Christodoulou and Suresh Chinthakunta and Divya Reddy and Saif Khalil and Thomas Apostolou and Philipp Drees and Konstantinos Kafchitsas},
title = {Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw},
journal = {Scoliosis},
year = {2015},
volume = {10},
publisher = {Springer Nature},
month = {may},
url = {https://doi.org/10.1186/s13013-015-0039-6},
number = {1},
pages = {15},
doi = {10.1186/s13013-015-0039-6}
}