Open Access
Development of HPLC method for quantitative determination of epimidin - new perspective АPhI with anticonvulsive activity
1
National University of Pharmacy Pushkinska str., 53, Kharkiv, Ukraine, 61002
|
Publication type: Journal Article
Publication date: 2020-06-30
—
scimago Q3
SJR: 0.191
CiteScore: 1.6
Impact factor: —
ISSN: 25194844, 25194852
Abstract
The aim. Development of optimal, high-precision and reproducible methods for quantitative determination of the main substance in the substance Epimidin - 1-(4-methoxyphenyl)-5-[2-[4-(4-methoxyphenyl)piperazin-1-yl]-2-oxo-ethyl]pyrazolo[3,4-d]pyrimidin-4-one by high performance liquid chromatography.Materials and methods. High performance liquid chromatography (HPLC) was performed using a ShimadzuNexeraX2 LC-30AD system (Shimadzu, Japan) equipped with a SPD-M20A diode array detector (DAD). ACE C18 column, size 250 x 4.6 mm, YMC with pre-column, particle size 5 μm, filled with octylsilyl silica gel for chromatography P. During the work acetonitrile and trifluoroacetic acid of HPLC class (Sigma-AldrichGmbH, Switzerland) were used, other chemicals and solvents were of analytical grade. In the study an analytical ware class A were used that meet the requirements of SPhU.Results. The following optimal conditions of chromatographic distribution are established: column C18 (250*4.6 mm); the speed of the mobile phase 1 ml / min; column thermostat temperature 35 °С; injection volume 10 μl; mobile phase A - 0.1 % trifluoroacetic acid; mobile phase B - acetonitrile P; the detection wavelength is 270 nm, the retention time of the test compound is 7.22 minutes. The performance of the column was determined for its main indicators, such as the number of theoretical plates (more than 25410) and the coefficient of symmetry (about 1.00). The technique was tested for the influence of various factors, such as flow rate, mobile phase composition and column thermostat temperature. It was established that the influence of these factors is insignificant and does not affect the results obtained by this method. The method was validated in accordance with the recommendations of SPhU on the parameters of specificity, linearity, correctness, precision, robustness (stability).Conclusions. For the first time, a high-precision and reproducible method for quantitative determination of the main substance in the substance Epimidin with anticonvulsant activity by high-performance liquid chromatography was developed. Conditions for chromatographic analysis (HPLC) were standardized. The requirements for the test “System suitability test criteria for chromatographic methods” are set. Statistical processing of the experimental results shows that the relative uncertainty of the average result is within acceptable limits. The correctness of the method was confirmed by validation studies. The developed technique will be used for pharmaceutical development and standardization of dosage form
Found
Nothing found, try to update filter.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
0
Total citations:
0
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Severina H. et al. Development of HPLC method for quantitative determination of epimidin - new perspective АPhI with anticonvulsive activity // ScienceRise: Pharmaceutical Science. 2020. Vol. 3 (25). pp. 4-11.
GOST all authors (up to 50)
Copy
Severina H., Bezruk I., Ivanauskas L., Georgiyants V. A. Development of HPLC method for quantitative determination of epimidin - new perspective АPhI with anticonvulsive activity // ScienceRise: Pharmaceutical Science. 2020. Vol. 3 (25). pp. 4-11.
Cite this
RIS
Copy
TY - JOUR
DO - 10.15587/2519-4852.2020.203181
UR - https://doi.org/10.15587/2519-4852.2020.203181
TI - Development of HPLC method for quantitative determination of epimidin - new perspective АPhI with anticonvulsive activity
T2 - ScienceRise: Pharmaceutical Science
AU - Severina, Hanna
AU - Bezruk, Ivan
AU - Ivanauskas, Liudas
AU - Georgiyants, Victoriya A.
PY - 2020
DA - 2020/06/30
SP - 4-11
IS - 3 (25)
SN - 2519-4844
SN - 2519-4852
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2020_Severina,
author = {Hanna Severina and Ivan Bezruk and Liudas Ivanauskas and Victoriya A. Georgiyants},
title = {Development of HPLC method for quantitative determination of epimidin - new perspective АPhI with anticonvulsive activity},
journal = {ScienceRise: Pharmaceutical Science},
year = {2020},
month = {jun},
url = {https://doi.org/10.15587/2519-4852.2020.203181},
number = {3 (25)},
pages = {4--11},
doi = {10.15587/2519-4852.2020.203181}
}