Open Access
Open access
Brazilian Dental Journal, volume 25, issue 1, pages 33-37

Addition of Chlorhexidine Gluconate to a Glass Ionomer Cement: A Study on Mechanical, Physical and Antibacterial Properties

Luana Mafra MARTI 1
Margareth da MATA 1
Beatriz Ferraz-Santos 1
Elcilaine Rizzato Azevedo 1
Elisa Maria Aparecida Giro 1
Angela Cristina Cilense Zuanon 1
Publication typeJournal Article
Publication date2014-01-01
scimago Q2
SJR0.406
CiteScore2.2
Impact factor
ISSN01036440, 18064760
General Dentistry
Abstract

The objective of this work was to determine the effect of different concentrations of chlorhexidine digluconate (CHX) on setting time, surface hardness, maximum tensile bond strength and antibacterial activity of a glass ionomer cement (GIC). The material used as control was Ketac Molar Easymix GIC. CHX was incorporated into the GIC during its manipulation at concentrations of 0.5, 1.0 and 2.0%. Antimicrobial activity against S. mutans and L. acidophilus was evaluated by means of agar diffusion test. Tensile bond strength data were analyzed statistically using Analysis of variance and Tukey's test. Setting time, Vickers hardness and agar diffusion test were analyzed using Kruskal-Wallis and Mann-Whitney tests at a significance level of 5%. It was observed that adding CHX at concentrations of 1% and 2% increased significantly the setting time of the material (p=0.012 and p=0.003, respectively). There was no significant difference between control and 0.5% CHX groups regarding the setting time. Addition of 2% CHX decreased significantly the surface hardness in relation to the control group (p=0.009), followed by the 1% CHX group (p=0.009). The tensile bond strength of the material also decreased significantly after adding CHX at a concentration of 2% (p=0.001). Addition of CHX promoted formation of an inhibition halo in both bacterial strains for all concentrations. The results showed that the best option for clinical use of GIC with CHX is at 0.5% concentration, since antibacterial activity increased and the physical-mechanical properties remained unchanged.

Found 
Found 

Top-30

Journals

1
2
3
4
1
2
3
4

Publishers

2
4
6
8
10
12
14
2
4
6
8
10
12
14
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex | MLA
Found error?