Open Access
Open access
volume 15 issue 3 pages 1237

Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs

Publication typeJournal Article
Publication date2025-01-25
scimago Q2
wos Q2
SJR0.521
CiteScore5.5
Impact factor2.5
ISSN20763417
Abstract

Background/Objectives: Internal implant–abutment connection has been proposed to increase interface stability and reduce biological and prosthetic issues. The aim of the present investigation was to evaluate the influence of the implant abutment conical angle on marginal bone loss and mechanical complications. Methods: The literature screening was performed by considering Pubmed/MEDLINE, EMBASE, and Google Scholar sources. The eligibility process was conducted in order to perform a descriptive synthesis, determine the risk of bias, and carry out network meta-analyses. The following categories were considered for pairwise comparisons: external hexagon (EI), internal hexagon (HI), cone morse (CM) (<8° contact angle), and conometric joint (>8° contact angle). For the descriptive data synthesis, the following parameters were considered: sample size, implant manufacturer, prosthetic joint type, prosthetic complications, marginal bone loss, and study outcomes. Results: A total of 4457 articles were screened, reducing the output to the 133 studies included in the descriptive synthesis, while 12 articles were included in the statistical analysis. No significant differences in marginal bone loss were reported when comparing a cone angle of <8° and a cone angle of >8; Conclusions: Within the limits of the present investigation, the cone interface seems to produce lower marginal bone loss compared to external and internal hexagon connection. No differences were found when comparing a cone angle of <8° and a cone angle of >8°.

Found 
Found 

Top-30

Journals

1
Materials
1 publication, 50%
BMC Oral Health
1 publication, 50%
1

Publishers

1
MDPI
1 publication, 50%
Springer Nature
1 publication, 50%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
2
Share
Cite this
GOST |
Cite this
GOST Copy
Alla I. et al. Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs // Applied Sciences (Switzerland). 2025. Vol. 15. No. 3. p. 1237.
GOST all authors (up to 50) Copy
Alla I., Scarano A., Sinjari B., Xhajanka E., Lorusso F. Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs // Applied Sciences (Switzerland). 2025. Vol. 15. No. 3. p. 1237.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.3390/app15031237
UR - https://www.mdpi.com/2076-3417/15/3/1237
TI - Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs
T2 - Applied Sciences (Switzerland)
AU - Alla, Iris
AU - Scarano, Antonio
AU - Sinjari, Bruna
AU - Xhajanka, Edit
AU - Lorusso, F.
PY - 2025
DA - 2025/01/25
PB - MDPI
SP - 1237
IS - 3
VL - 15
SN - 2076-3417
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2025_Alla,
author = {Iris Alla and Antonio Scarano and Bruna Sinjari and Edit Xhajanka and F. Lorusso},
title = {Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs},
journal = {Applied Sciences (Switzerland)},
year = {2025},
volume = {15},
publisher = {MDPI},
month = {jan},
url = {https://www.mdpi.com/2076-3417/15/3/1237},
number = {3},
pages = {1237},
doi = {10.3390/app15031237}
}
MLA
Cite this
MLA Copy
Alla, Iris, et al. “Peri-Implant Bone Stability Around Tapered Implant Prosthetic Connection: A Systematic Review and Meta-Analysis Comparing Different Cone Morse and Conometric Implants Angle Contact and Coupling Interface Designs.” Applied Sciences (Switzerland), vol. 15, no. 3, Jan. 2025, p. 1237. https://www.mdpi.com/2076-3417/15/3/1237.