Open Access
Open access
том 13 издание 22 страницы 6961

Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter

Тип публикацииJournal Article
Дата публикации2024-11-19
scimago Q1
wos Q1
БС1
SJR0.919
CiteScore5.2
Impact factor2.9
ISSN20770383
Краткое описание

Background and Aims: Various pulsed field ablation (PFA) systems are currently being developed. Recently, a novel CE-approved circular array PFA catheter (PulseSelect™ PFA System, Medtronic, Minneapolis, MN, USA) was introduced. Data on this commercially available system are sparse. The aim was to elucidate real-world data assessing the feasibility, safety, and acute efficacy of pulmonary vein isolation (PVI) and ablation beyond PVI with this novel ablation system. Methods: Consecutive patients with paroxysmal and persistent atrial fibrillation (AF) undergoing first-time ablation with the circular PFA catheter were enrolled in this study. In patients with persistent AF and left atrial (LA) enlargement (LA area > 20 cm2), additional left atrial roof ablation (LARA) was performed. Those with concomitant typical atrial flutter received adjunctive cavo-tricuspid isthmus (CTI) ablation. Results: A total of 100 AF patients were included (29% female, 50% persistent AF). Of these, 33 patients (33%) underwent adjunctive LARA, 1 patient (1%) received posterior wall isolation, and 6 patients (6%) required additional CTI ablation. The skin-to-skin procedural time averaged 66.3 ± 13.8 min, while the fluoroscopy time and dose area product were 13.7 ± 4.7 min and 6.8 ± 4.9 Gycm2, respectively. Acute PVI was achieved in 100% of pulmonary veins. A bidirectional conduction block of the LARA and CTI lines was confirmed in all patients, and no major adverse events were reported. Conclusions: These real-world data demonstrate the feasibility, safety, and acute efficacy of PVI and ablation beyond PVI using a novel circular array PFA catheter in patients with atrial fibrillation and flutter. The system can easily be integrated with standard PVI workflows. Further and larger studies are warranted to assess the clinical long-term effectiveness and safety of this PFA system.

Найдено 
Найдено 

Топ-30

Журналы

1
2
Heart Rhythm O2
2 публикации, 50%
Journal of Cardiovascular Electrophysiology
1 публикация, 25%
Journal of Interventional Cardiac Electrophysiology
1 публикация, 25%
1
2

Издатели

1
2
Elsevier
2 публикации, 50%
Wiley
1 публикация, 25%
Springer Nature
1 публикация, 25%
1
2
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
4
Поделиться
Цитировать
ГОСТ |
Цитировать
Yogarajah J. et al. Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter // Journal of Clinical Medicine. 2024. Vol. 13. No. 22. p. 6961.
ГОСТ со всеми авторами (до 50) Скопировать
Yogarajah J., Hutter J., Kahle P., Beaujean P., Tomic M., Hain A., Sossalla S., Kuniss M., Neumann T. Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter // Journal of Clinical Medicine. 2024. Vol. 13. No. 22. p. 6961.
RIS |
Цитировать
TY - JOUR
DO - 10.3390/jcm13226961
UR - https://www.mdpi.com/2077-0383/13/22/6961
TI - Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter
T2 - Journal of Clinical Medicine
AU - Yogarajah, Joerg
AU - Hutter, Julie
AU - Kahle, Patrick
AU - Beaujean, Philipp
AU - Tomic, Marko
AU - Hain, Andreas
AU - Sossalla, Samuel
AU - Kuniss, Malte
AU - Neumann, Thomas
PY - 2024
DA - 2024/11/19
PB - MDPI
SP - 6961
IS - 22
VL - 13
PMID - 39598104
SN - 2077-0383
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2024_Yogarajah,
author = {Joerg Yogarajah and Julie Hutter and Patrick Kahle and Philipp Beaujean and Marko Tomic and Andreas Hain and Samuel Sossalla and Malte Kuniss and Thomas Neumann},
title = {Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
publisher = {MDPI},
month = {nov},
url = {https://www.mdpi.com/2077-0383/13/22/6961},
number = {22},
pages = {6961},
doi = {10.3390/jcm13226961}
}
MLA
Цитировать
Yogarajah, Joerg, et al. “Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter.” Journal of Clinical Medicine, vol. 13, no. 22, Nov. 2024, p. 6961. https://www.mdpi.com/2077-0383/13/22/6961.