Open Access
Open access
том 9 издание 3 страницы 84

Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera

Тип публикацииJournal Article
Дата публикации2019-06-30
SCImago Q1
WOS Q1
БС1
SJR0.886
CiteScore9.8
Impact factor5.6
ISSN20796374, 0265928X
General Medicine
Clinical Biochemistry
Краткое описание

The electrochemical aptamer sensor has been designed for detecting tau381, a critical biomarker of Alzheimer′s disease in human serum. The aptasensor is obtained by immobilizing the aptamer on a carboxyl graphene/thionin/gold nanoparticle modified glassy-carbon electrode. As a probe and bridge molecule, thionin connected carboxyl graphene and gold nanoparticles, and gave the electrical signal. Under optimal conditions, the increment of differential pulse voltammetry signal increased linearly with the logarithm of tau381 concentration in the range from 1.0 pM to 100 pM, and limit of detection was 0.70 pM. The aptasensor reliability was evaluated by determining its selectivity, reproducibility, stability, detection limit, and recovery. Performance analysis of the tau381 aptasensor in 10 patients’ serum samples showed that the aptasensor could screen patients with and without Alzheimer′s disease. The proposed aptasensor has potential for use in clinically diagnosing Alzheimer′s disease in the early stage.

Для доступа к списку цитирований публикации необходимо авторизоваться.
Для доступа к списку профилей, цитирующих публикацию, необходимо авторизоваться.

Топ-30

Журналы

1
2
3
4
5
6
Biosensors
6 публикаций, 8.33%
Chemosensors
3 публикации, 4.17%
Journal of Pharmaceutical and Biomedical Analysis
3 публикации, 4.17%
Current Opinion in Electrochemistry
3 публикации, 4.17%
Biosensors and Bioelectronics: X
3 публикации, 4.17%
Sensors
2 публикации, 2.78%
Molecules
2 публикации, 2.78%
Sensors and Actuators, B: Chemical
2 публикации, 2.78%
Biosensors and Bioelectronics
2 публикации, 2.78%
RSC Advances
2 публикации, 2.78%
Bulletin of the Korean Chemical Society
1 публикация, 1.39%
Current Pharmaceutical Design
1 публикация, 1.39%
Current Medicinal Chemistry
1 публикация, 1.39%
Nucleic Acid Therapeutics
1 публикация, 1.39%
TrAC - Trends in Analytical Chemistry
1 публикация, 1.39%
Biomaterials Advances
1 публикация, 1.39%
Diagnostics
1 публикация, 1.39%
Coatings
1 публикация, 1.39%
Microchimica Acta
1 публикация, 1.39%
Analytical and Bioanalytical Chemistry
1 публикация, 1.39%
Nanomedicine: Nanotechnology, Biology, and Medicine
1 публикация, 1.39%
Talanta
1 публикация, 1.39%
Microfluidics and Nanofluidics
1 публикация, 1.39%
Journal of Hazardous Materials
1 публикация, 1.39%
International Journal of Biological Macromolecules
1 публикация, 1.39%
Analytical Chemistry
1 публикация, 1.39%
ACS applied materials & interfaces
1 публикация, 1.39%
Carbon Letters
1 публикация, 1.39%
Advanced Therapeutics
1 публикация, 1.39%
1
2
3
4
5
6

Издатели

5
10
15
20
25
30
Elsevier
26 публикаций, 36.11%
MDPI
17 публикаций, 23.61%
Springer Nature
11 публикаций, 15.28%
Wiley
5 публикаций, 6.94%
Royal Society of Chemistry (RSC)
3 публикации, 4.17%
Bentham Science Publishers Ltd.
2 публикации, 2.78%
American Chemical Society (ACS)
2 публикации, 2.78%
Taylor & Francis
2 публикации, 2.78%
Mary Ann Liebert
1 публикация, 1.39%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 1.39%
openRxiv
1 публикация, 1.39%
5
10
15
20
25
30
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
72
Поделиться
Цитировать
ГОСТ |
Цитировать
Tao D. et al. Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera // Biosensors. 2019. Vol. 9. No. 3. p. 84.
ГОСТ со всеми авторами (до 50) Скопировать
Tao D., Shui B., Gu Y., Cheng J., Zhang W., Jaffrezic-Renault N., Song S., Guo Z. Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera // Biosensors. 2019. Vol. 9. No. 3. p. 84.
RIS |
Цитировать
TY - JOUR
DO - 10.3390/bios9030084
UR - https://www.mdpi.com/2079-6374/9/3/84
TI - Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera
T2 - Biosensors
AU - Tao, Dan
AU - Shui, Bingqing
AU - Gu, Yingying
AU - Cheng, Jing
AU - Zhang, Weiying
AU - Jaffrezic-Renault, N.
AU - Song, Shizhen
AU - Guo, Zhenzhong
PY - 2019
DA - 2019/06/30
PB - MDPI
SP - 84
IS - 3
VL - 9
PMID - 31262001
SN - 2079-6374
SN - 0265-928X
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2019_Tao,
author = {Dan Tao and Bingqing Shui and Yingying Gu and Jing Cheng and Weiying Zhang and N. Jaffrezic-Renault and Shizhen Song and Zhenzhong Guo},
title = {Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera},
journal = {Biosensors},
year = {2019},
volume = {9},
publisher = {MDPI},
month = {jun},
url = {https://www.mdpi.com/2079-6374/9/3/84},
number = {3},
pages = {84},
doi = {10.3390/bios9030084}
}
MLA
Цитировать
Tao, Dan, et al. “Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients’ Sera.” Biosensors, vol. 9, no. 3, Jun. 2019, p. 84. https://www.mdpi.com/2079-6374/9/3/84.
Ошибка в публикации?