To introduce a new, minimally invasive intrastromal correction for presbyopia (INTRACOR procedure) using the TECHNOLAS femtosecond laser system (Technolas Perfect Vision GmbH).The INTRACOR procedure was performed in 83 eyes of 45 patients aged 44 to 67 years. Follow-up was 6 to 12 months. Data recorded included age; pre- and postoperative refraction; uncorrected distance (UDVA), intermediate, and near visual acuity (UNVA); corrected distance visual acuity (CDVA); distance corrected near visual acuity; corneal hysteresis (CH), corneal resistance factor (CRF), and asphericity; pachymetry; endothelial cell density; contrast sensitivity; and ocular aberrations.At 6 months postoperatively, all 83 (100%) eyes had improved UNVA, with minimal or no change in UDVA. Twenty-two eyes were available at 12 months; UNVA improved to J1 in these eyes with continued improvement in mean UDVA. At last follow-up, a mild myopic shift in refraction was noted with only 3 (3.6%) eyes showing a 2- or 3-line decrease of UDVA, and 74 (89.2%) eyes achieved both J2 and 20/25 or better. Mean CDVA and distance corrected near visual acuity continued to improve with time. Two (2.4%) eyes lost 2 lines of CDVA at 6 months, but this did not occur in the 22 eyes seen at 1 year. Overall stability was noted in CH, CRF, pachymetry, endothelial cell density, and contrast sensitivity. Primary spherical aberrations shifted toward negative values and secondary spherical aberration shifted toward positive values. No corneal structural complications were observed.The INTRACOR intrastromal procedure using the TECHNOLAS femtosecond laser is a promising procedure for presbyopia correction. It preserves the corneal epithelium and anterior stromal fibers.
Found 

Top-30

Journals

2
4
6
8
10
12
Journal of Refractive Surgery
11 publications, 17.74%
Journal of Cataract and Refractive Surgery
8 publications, 12.9%
Ophthalmologe
4 publications, 6.45%
International Ophthalmology Clinics
3 publications, 4.84%
British Journal of Ophthalmology
3 publications, 4.84%
Eye and Contact Lens
2 publications, 3.23%
Techniques in Ophthalmology
2 publications, 3.23%
Eye and Vision
2 publications, 3.23%
Cornea
1 publication, 1.61%
Current Opinion in Ophthalmology
1 publication, 1.61%
European Journal of Ophthalmology
1 publication, 1.61%
Graefe's Archive for Clinical and Experimental Ophthalmology
1 publication, 1.61%
Journal of Materials Science: Materials in Medicine
1 publication, 1.61%
Current Ophthalmology Reports
1 publication, 1.61%
Canadian Journal of Ophthalmology
1 publication, 1.61%
Journal Francais d'Ophtalmologie
1 publication, 1.61%
American Journal of Ophthalmology
1 publication, 1.61%
Experimental Eye Research
1 publication, 1.61%
Ophthalmic and Physiological Optics
1 publication, 1.61%
Acta Ophthalmologica
1 publication, 1.61%
Seminars in Ophthalmology
1 publication, 1.61%
Expert Review of Medical Devices
1 publication, 1.61%
Asia-Pacific Journal of Ophthalmology
1 publication, 1.61%
Applied Optics
1 publication, 1.61%
Current Advances in Ocular Surgery
1 publication, 1.61%
Taiwan Journal of Ophthalmology
1 publication, 1.61%
Journal of Ocular Pharmacology and Therapeutics
1 publication, 1.61%
2
4
6
8
10
12

Publishers

2
4
6
8
10
12
14
16
18
20
Ovid Technologies (Wolters Kluwer Health)
19 publications, 30.65%
SLACK
11 publications, 17.74%
Springer Nature
10 publications, 16.13%
Elsevier
5 publications, 8.06%
Wiley
3 publications, 4.84%
BMJ
3 publications, 4.84%
Taylor & Francis
2 publications, 3.23%
SAGE
1 publication, 1.61%
Optica Publishing Group
1 publication, 1.61%
Mary Ann Liebert
1 publication, 1.61%
2
4
6
8
10
12
14
16
18
20
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
62
Share
Cite this
GOST |
Cite this
GOST Copy
Ruiz L. A. Intrastromal Correction of Presbyopia Using a Femtosecond Laser System // Journal of Refractive Surgery. 2009. Vol. 25. No. 10. pp. 847-854.
GOST all authors (up to 50) Copy
Ruiz L. A. Intrastromal Correction of Presbyopia Using a Femtosecond Laser System // Journal of Refractive Surgery. 2009. Vol. 25. No. 10. pp. 847-854.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.3928/1081597X-20090917-05
UR - https://doi.org/10.3928/1081597X-20090917-05
TI - Intrastromal Correction of Presbyopia Using a Femtosecond Laser System
T2 - Journal of Refractive Surgery
AU - Ruiz, Luis Antonio
PY - 2009
DA - 2009/01/01
PB - SLACK
SP - 847-854
IS - 10
VL - 25
PMID - 19835324
SN - 1081-597X
SN - 1938-2391
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2009_Ruiz,
author = {Luis Antonio Ruiz},
title = {Intrastromal Correction of Presbyopia Using a Femtosecond Laser System},
journal = {Journal of Refractive Surgery},
year = {2009},
volume = {25},
publisher = {SLACK},
month = {jan},
url = {https://doi.org/10.3928/1081597X-20090917-05},
number = {10},
pages = {847--854},
doi = {10.3928/1081597X-20090917-05}
}
MLA
Cite this
MLA Copy
Ruiz, Luis Antonio, et al. “Intrastromal Correction of Presbyopia Using a Femtosecond Laser System.” Journal of Refractive Surgery, vol. 25, no. 10, Jan. 2009, pp. 847-854. https://doi.org/10.3928/1081597X-20090917-05.