том 57 издание 6 страницы 396-400

Efficiency of ultrasound color flow imaging in the presence of twinkling artifact

Тип публикацииJournal Article
Дата публикации2024-03-25
scimago Q3
wos Q4
БС4
SJR0.164
CiteScore0.9
Impact factor0.3
ISSN00063398, 15738256
Medicine (miscellaneous)
Biomedical Engineering
Medical Laboratory Technology
Краткое описание
Traditional blood flow mapping algorithms are not effective enough when the region of interest contains the sources of artifacts. This paper examines the signatures of blood flow signals, as well as noise and artifact signals. Mathematical rules are proposed on the basis of these features to discriminate the blood flow signal from other signals, including the Doppler twinkling artifact. The diagnostic efficiency of the proposed decision rules is assessed using the previously collected database of raw ultrasound Doppler signals. The study results showed that taking account of the spatial stability of blood flow velocity can increase diagnostic efficiency to 91.6%.
Найдено 

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
0
Поделиться
Цитировать
ГОСТ |
Цитировать
Leonov D. V. Efficiency of ultrasound color flow imaging in the presence of twinkling artifact // Bio-Medical Engineering. 2024. Vol. 57. No. 6. pp. 396-400.
ГОСТ со всеми авторами (до 50) Скопировать
Leonov D. V. Efficiency of ultrasound color flow imaging in the presence of twinkling artifact // Bio-Medical Engineering. 2024. Vol. 57. No. 6. pp. 396-400.
RIS |
Цитировать
TY - JOUR
DO - 10.1007/s10527-024-10343-w
UR - https://doi.org/10.1007/s10527-024-10343-w
TI - Efficiency of ultrasound color flow imaging in the presence of twinkling artifact
T2 - Bio-Medical Engineering
AU - Leonov, D. V.
PY - 2024
DA - 2024/03/25
PB - Springer Nature
SP - 396-400
IS - 6
VL - 57
SN - 0006-3398
SN - 1573-8256
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2024_Leonov,
author = {D. V. Leonov},
title = {Efficiency of ultrasound color flow imaging in the presence of twinkling artifact},
journal = {Bio-Medical Engineering},
year = {2024},
volume = {57},
publisher = {Springer Nature},
month = {mar},
url = {https://doi.org/10.1007/s10527-024-10343-w},
number = {6},
pages = {396--400},
doi = {10.1007/s10527-024-10343-w}
}
MLA
Цитировать
Leonov, D. V.. “Efficiency of ultrasound color flow imaging in the presence of twinkling artifact.” Bio-Medical Engineering, vol. 57, no. 6, Mar. 2024, pp. 396-400. https://doi.org/10.1007/s10527-024-10343-w.