Open Access
Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking
Publication type: Journal Article
Publication date: 2017-11-01
scimago Q2
wos Q1
SJR: 0.603
CiteScore: 3.8
Impact factor: 3.8
ISSN: 10159584, 02193108
PubMed ID:
27522171
Surgery
Abstract
This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM).Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated.The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage.The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
|
|
|
Journal of Orthopaedic Surgery and Research
2 publications, 9.09%
|
|
|
Soft Matter
2 publications, 9.09%
|
|
|
Industrial Lubrication and Tribology
1 publication, 4.55%
|
|
|
Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
1 publication, 4.55%
|
|
|
Processes
1 publication, 4.55%
|
|
|
Scientific Reports
1 publication, 4.55%
|
|
|
IOP Conference Series: Materials Science and Engineering
1 publication, 4.55%
|
|
|
Journal of the Mechanical Behavior of Biomedical Materials
1 publication, 4.55%
|
|
|
Procedia CIRP
1 publication, 4.55%
|
|
|
Journal of Biomechanics
1 publication, 4.55%
|
|
|
Corrosion Science
1 publication, 4.55%
|
|
|
Tribology - Materials, Surfaces and Interfaces
1 publication, 4.55%
|
|
|
Biomechanics and Modeling in Mechanobiology
1 publication, 4.55%
|
|
|
Mechanisms and Machine Science
1 publication, 4.55%
|
|
|
AIP Advances
1 publication, 4.55%
|
|
|
Journal of Orthopaedic Translation
1 publication, 4.55%
|
|
|
The Journal of the American Academy of Orthopaedic Surgeons
1 publication, 4.55%
|
|
|
1
2
|
Publishers
|
1
2
3
4
5
6
|
|
|
Springer Nature
6 publications, 27.27%
|
|
|
Elsevier
5 publications, 22.73%
|
|
|
Royal Society of Chemistry (RSC)
2 publications, 9.09%
|
|
|
Emerald
1 publication, 4.55%
|
|
|
SAGE
1 publication, 4.55%
|
|
|
MDPI
1 publication, 4.55%
|
|
|
IOP Publishing
1 publication, 4.55%
|
|
|
Taylor & Francis
1 publication, 4.55%
|
|
|
Association for Computing Machinery (ACM)
1 publication, 4.55%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 4.55%
|
|
|
AIP Publishing
1 publication, 4.55%
|
|
|
Ovid Technologies (Wolters Kluwer Health)
1 publication, 4.55%
|
|
|
1
2
3
4
5
6
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
22
Total citations:
22
Citations from 2024:
5
(22.73%)
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Wang G. et al. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking // Asian Journal of Surgery. 2017. Vol. 40. No. 6. pp. 463-469.
GOST all authors (up to 50)
Copy
Wang G., Huang W., Song Q., Liang J. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking // Asian Journal of Surgery. 2017. Vol. 40. No. 6. pp. 463-469.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.asjsur.2016.07.002
UR - https://doi.org/10.1016/j.asjsur.2016.07.002
TI - Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking
T2 - Asian Journal of Surgery
AU - Wang, Guangye
AU - Huang, Wenjun
AU - Song, Qi
AU - Liang, Jinfeng
PY - 2017
DA - 2017/11/01
PB - Elsevier
SP - 463-469
IS - 6
VL - 40
PMID - 27522171
SN - 1015-9584
SN - 0219-3108
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2017_Wang,
author = {Guangye Wang and Wenjun Huang and Qi Song and Jinfeng Liang},
title = {Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking},
journal = {Asian Journal of Surgery},
year = {2017},
volume = {40},
publisher = {Elsevier},
month = {nov},
url = {https://doi.org/10.1016/j.asjsur.2016.07.002},
number = {6},
pages = {463--469},
doi = {10.1016/j.asjsur.2016.07.002}
}
Cite this
MLA
Copy
Wang, Guangye, et al. “Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.” Asian Journal of Surgery, vol. 40, no. 6, Nov. 2017, pp. 463-469. https://doi.org/10.1016/j.asjsur.2016.07.002.