Stroke identification using a portable EEG device – A pilot study
Matan Gottlibe
1
,
Oren Rosen
2
,
Boaz Weller
3, 4
,
Mahagney Ayed
4
,
Nicola Omar
4
,
Ala Khuri
4
,
Isaac Srugo
3, 5
,
Jacob Genizi
3, 6
Publication type: Journal Article
Publication date: 2020-02-01
scimago Q2
wos Q2
SJR: 0.871
CiteScore: 5.3
Impact factor: 2.4
ISSN: 09877053, 17697131
PubMed ID:
32014371
General Medicine
Neurology
Physiology (medical)
Neurology (clinical)
Abstract
Summary Objective Changes in EEG patterns during stroke are almost immediate; however, a full EEG test takes time and requires highly qualified staff. In this study, we examined whether a short recording using a portable EEG device can differentiate between a stroke and control group. Methods EEG samples were collected from patients with an acute ischemic stroke event. The control group comprised healthy volunteers. EEG recordings were recorded using a portable brain wave sensor device. The Revised Brain Symmetry Index (rsBSI) was used to quantify the symmetry of spectral power between the two hemispheres. Results The investigation group included 33 patients (ages 46–96, mean age 72 years, 66% male) who were diagnosed with ischemic stroke. The control group included 25 healthy individuals. Scores for the rsBSI of non-stroke patients (M = 0.1686, SD = 0.10) differed significantly from those of ischemic stroke patients (P Conclusions A statistically significant difference was observed between a group of stroke patients and a matched group of healthy controls with a short recording using a portable EEG device.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
|
|
|
Sensors
3 publications, 7.5%
|
|
|
BMC Emergency Medicine
2 publications, 5%
|
|
|
Journal of Clinical Neurophysiology
2 publications, 5%
|
|
|
Stroke
1 publication, 2.5%
|
|
|
Medicine (United States)
1 publication, 2.5%
|
|
|
Neurosurgical Focus
1 publication, 2.5%
|
|
|
Journal of Cerebral Blood Flow and Metabolism
1 publication, 2.5%
|
|
|
Cognitive Neurodynamics
1 publication, 2.5%
|
|
|
Scientific Reports
1 publication, 2.5%
|
|
|
Computers in Biology and Medicine
1 publication, 2.5%
|
|
|
Prehospital Emergency Care
1 publication, 2.5%
|
|
|
IEEE Access
1 publication, 2.5%
|
|
|
Communications in Computer and Information Science
1 publication, 2.5%
|
|
|
Lecture Notes in Electrical Engineering
1 publication, 2.5%
|
|
|
Advanced Biology
1 publication, 2.5%
|
|
|
PLOS Digital Health
1 publication, 2.5%
|
|
|
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
1 publication, 2.5%
|
|
|
Biomedical Signal Processing and Control
1 publication, 2.5%
|
|
|
Handbook of Research on Global Business Opportunities
1 publication, 2.5%
|
|
|
Journal of the American Heart Association
1 publication, 2.5%
|
|
|
IEEE Transactions on Emerging Topics in Computational Intelligence
1 publication, 2.5%
|
|
|
Journal of Speech, Language, and Hearing Research
1 publication, 2.5%
|
|
|
IEEE Internet of Things Journal
1 publication, 2.5%
|
|
|
Annals of Clinical and Translational Neurology
1 publication, 2.5%
|
|
|
Brain Topography
1 publication, 2.5%
|
|
|
IEEE Transactions on Neural Systems and Rehabilitation Engineering
1 publication, 2.5%
|
|
|
Neurology International
1 publication, 2.5%
|
|
|
BMJ Open
1 publication, 2.5%
|
|
|
1
2
3
|
Publishers
|
2
4
6
8
10
12
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
11 publications, 27.5%
|
|
|
Springer Nature
7 publications, 17.5%
|
|
|
Ovid Technologies (Wolters Kluwer Health)
4 publications, 10%
|
|
|
MDPI
4 publications, 10%
|
|
|
Wiley
3 publications, 7.5%
|
|
|
Elsevier
2 publications, 5%
|
|
|
Cold Spring Harbor Laboratory
2 publications, 5%
|
|
|
Journal of Neurosurgery Publishing Group (JNSPG)
1 publication, 2.5%
|
|
|
SAGE
1 publication, 2.5%
|
|
|
Taylor & Francis
1 publication, 2.5%
|
|
|
Public Library of Science (PLoS)
1 publication, 2.5%
|
|
|
IGI Global
1 publication, 2.5%
|
|
|
American Speech Language Hearing Association
1 publication, 2.5%
|
|
|
BMJ
1 publication, 2.5%
|
|
|
2
4
6
8
10
12
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
40
Total citations:
40
Citations from 2024:
10
(25%)
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Gottlibe M. et al. Stroke identification using a portable EEG device – A pilot study // Neurophysiologie Clinique. 2020. Vol. 50. No. 1. pp. 21-25.
GOST all authors (up to 50)
Copy
Gottlibe M., Rosen O., Weller B., Ayed M., Omar N., Khuri A., Srugo I., Genizi J. Stroke identification using a portable EEG device – A pilot study // Neurophysiologie Clinique. 2020. Vol. 50. No. 1. pp. 21-25.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.neucli.2019.12.004
UR - https://doi.org/10.1016/j.neucli.2019.12.004
TI - Stroke identification using a portable EEG device – A pilot study
T2 - Neurophysiologie Clinique
AU - Gottlibe, Matan
AU - Rosen, Oren
AU - Weller, Boaz
AU - Ayed, Mahagney
AU - Omar, Nicola
AU - Khuri, Ala
AU - Srugo, Isaac
AU - Genizi, Jacob
PY - 2020
DA - 2020/02/01
PB - Elsevier
SP - 21-25
IS - 1
VL - 50
PMID - 32014371
SN - 0987-7053
SN - 1769-7131
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2020_Gottlibe,
author = {Matan Gottlibe and Oren Rosen and Boaz Weller and Mahagney Ayed and Nicola Omar and Ala Khuri and Isaac Srugo and Jacob Genizi},
title = {Stroke identification using a portable EEG device – A pilot study},
journal = {Neurophysiologie Clinique},
year = {2020},
volume = {50},
publisher = {Elsevier},
month = {feb},
url = {https://doi.org/10.1016/j.neucli.2019.12.004},
number = {1},
pages = {21--25},
doi = {10.1016/j.neucli.2019.12.004}
}
Cite this
MLA
Copy
Gottlibe, Matan, et al. “Stroke identification using a portable EEG device – A pilot study.” Neurophysiologie Clinique, vol. 50, no. 1, Feb. 2020, pp. 21-25. https://doi.org/10.1016/j.neucli.2019.12.004.