том 282 издание 2 страницы 101-112

Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts

Тип публикацииJournal Article
Дата публикации2020-12-24
scimago Q2
wos Q3
white level БС2
SJR0.513
CiteScore4.1
Impact factor1.9
ISSN00222720, 13652818
Histology
Pathology and Forensic Medicine
Краткое описание
Recently, the dual beam Xe+ plasma focused ion beam (Xe+ pFIB) instrument has attracted increasing interest for site-specific transmission electron microscopy (TEM) sample preparation for a local region of interest as it shows several potential benefits compared to conventional Ga+ FIB milling. Nevertheless, challenges and questions remain especially in terms of FIB-induced artefacts, which hinder reliable S/TEM microstructural and compositional analysis. Here we examine the efficacy of using Xe+ pFIB as compared with conventional Ga+ FIB for TEM sample preparation of Al alloys. Three potential source of specimen preparation artefacts were examined, namely: (1) implantation-induced defects such as amophisation, dislocations, or 'bubble' formation in the near-surface region resulting from ion bombardment of the sample by the incident beam; (2) compositional artefacts due to implantation of the source ions and (3) material redeposition due to the milling process. It is shown that Xe+ pFIB milling is able to produce improved STEM/TEM samples compared to those produced by Ga+ milling, and is therefore the preferred specimen preparation route. Strategies for minimising the artefacts induced by Xe+ pFIB and Ga+ FIB are also proposed. LAY DESCRIPTION: FIB (focused ion beam) instruments have become one of the most important systems in the preparation of site-specific TEM specimens, which are typically 50-100 nm in thickness. TEM specimen preparation of Al alloys is particularly challenging, as convention Ga-ion FIB produces artefacts in these materials that make microstructural analysis difficult or impossible. Recently, the use of noble gas ion sources, such as Xe, has markedly improved milling speeds and is being used for the preparation of various materials. Hence, it is necessary to investigate the structural defects formed during FIB milling and assess the ion-induced chemical contamination in these TEM samples. Here we explore the feasibility and efficiency of using Xe+ PFIB as a TEM sample preparation route for Al alloys in comparison with the conventional Ga+FIB.
Для доступа к списку цитирований публикации необходимо авторизоваться.
Для доступа к списку профилей, цитирующих публикацию, необходимо авторизоваться.

Топ-30

Журналы

1
2
3
4
5
6
Microscopy and Microanalysis
6 публикаций, 10.91%
Ultramicroscopy
4 публикации, 7.27%
Materials Characterization
3 публикации, 5.45%
Materialia
2 публикации, 3.64%
Advanced Engineering Materials
2 публикации, 3.64%
ACS Energy Letters
2 публикации, 3.64%
Acta Materialia
2 публикации, 3.64%
Scripta Materialia
2 публикации, 3.64%
Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films
1 публикация, 1.82%
Coatings
1 публикация, 1.82%
Science China Chemistry
1 публикация, 1.82%
Natural Sciences
1 публикация, 1.82%
Corrosion Science
1 публикация, 1.82%
Surface and Coatings Technology
1 публикация, 1.82%
Microscopy Research and Technique
1 публикация, 1.82%
ACS Nano
1 публикация, 1.82%
Nanoscale
1 публикация, 1.82%
Nanomaterials
1 публикация, 1.82%
Corrosion Engineering Science and Technology
1 публикация, 1.82%
bioRxiv
1 публикация, 1.82%
APL Materials
1 публикация, 1.82%
Proceedings of the National Academy of Sciences of the United States of America
1 публикация, 1.82%
Materials
1 публикация, 1.82%
MRS Bulletin
1 публикация, 1.82%
Applied Physics Reviews
1 публикация, 1.82%
Advanced Energy Materials
1 публикация, 1.82%
Nature Communications
1 публикация, 1.82%
European Journal of Materials
1 публикация, 1.82%
AIP Advances
1 публикация, 1.82%
International Journal of Metalcasting
1 публикация, 1.82%
1
2
3
4
5
6

Издатели

2
4
6
8
10
12
14
16
18
Elsevier
17 публикаций, 30.91%
Springer Nature
6 публикаций, 10.91%
Wiley
6 публикаций, 10.91%
Oxford University Press
6 публикаций, 10.91%
MDPI
4 публикации, 7.27%
American Chemical Society (ACS)
4 публикации, 7.27%
AIP Publishing
3 публикации, 5.45%
Royal Society of Chemistry (RSC)
2 публикации, 3.64%
American Vacuum Society
1 публикация, 1.82%
SAGE
1 публикация, 1.82%
openRxiv
1 публикация, 1.82%
Proceedings of the National Academy of Sciences (PNAS)
1 публикация, 1.82%
Cambridge University Press
1 публикация, 1.82%
Taylor & Francis
1 публикация, 1.82%
The Surface Analysis Society of Japan
1 публикация, 1.82%
2
4
6
8
10
12
14
16
18
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
56
Поделиться
Цитировать
ГОСТ |
Цитировать
Zhong X. et al. Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts // Journal of Microscopy. 2020. Vol. 282. No. 2. pp. 101-112.
ГОСТ со всеми авторами (до 50) Скопировать
Zhong X., Wade C. A., Withers P., Zhou X., Cai C., Haigh S. J., Burke M. S. Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts // Journal of Microscopy. 2020. Vol. 282. No. 2. pp. 101-112.
RIS |
Цитировать
TY - JOUR
DO - 10.1111/jmi.12983
UR - https://doi.org/10.1111/jmi.12983
TI - Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts
T2 - Journal of Microscopy
AU - Zhong, Xiangli
AU - Wade, C Austin
AU - Withers, Philip
AU - Zhou, Xiaorong
AU - Cai, Changrun
AU - Haigh, Sarah J.
AU - Burke, M Shannon
PY - 2020
DA - 2020/12/24
PB - Wiley
SP - 101-112
IS - 2
VL - 282
PMID - 33210738
SN - 0022-2720
SN - 1365-2818
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2020_Zhong,
author = {Xiangli Zhong and C Austin Wade and Philip Withers and Xiaorong Zhou and Changrun Cai and Sarah J. Haigh and M Shannon Burke},
title = {Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts},
journal = {Journal of Microscopy},
year = {2020},
volume = {282},
publisher = {Wiley},
month = {dec},
url = {https://doi.org/10.1111/jmi.12983},
number = {2},
pages = {101--112},
doi = {10.1111/jmi.12983}
}
MLA
Цитировать
Zhong, Xiangli, et al. “Comparing Xe + pFIB and Ga + FIB for TEM sample preparation of Al alloys: Minimising FIB‐induced artefacts.” Journal of Microscopy, vol. 282, no. 2, Dec. 2020, pp. 101-112. https://doi.org/10.1111/jmi.12983.
Ошибка в публикации?