ACS Applied Bio Materials, volume 2, issue 12, pages 5880-5887

Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat

Francesca Costantini 1
Nicola Lovecchio 2
Albert Ruggi 3
Cesare Manetti 4
Augusto Nascetti 5
Massimo Reverberi 4
Giampiero de Cesare 2
Domenico Caputo 2
Publication typeJournal Article
Publication date2019-11-07
Quartile SCImago
Q1
Quartile WOS
Q1
Impact factor4.6
ISSN25766422, 25766422
General Chemistry
Biomaterials
Biomedical Engineering
Biochemistry (medical)
Abstract
This paper reports on the development of a fluorescent label-free aptamer assay integrated in a lab-on-chip (LoC) system for the detection of Ochratoxin A (OTA). The detection system relies on the integration, on a single glass substrate, of an array of amorphous silicon photosensors and a long pass interferential filter. The aptamer assay, integrated into the microfluidic network, is an aptasensor having affinity versus OTA, selected as a case study. The fluorescent molecule is a "light switch" complex [Ru(phen)2(dppz)]2+. The aptamer is directly anchored into a layer of poly(2-hydroxyethyl methacrylate) polymer brushes grown inside the channels. The fluorophore is intercalated between the base pairs of the aptamer. Upon the interaction of OTA with the aptasensor, a change of the aptamer conformation causes the release of the fluorophore, yielding a decrease of the fluorescent signal detected by the array of the amorphous silicon photosensors positioned underneath the microfluidic network. The developed LoC is a portable system capable of performing the analysis with a small volume of sample (about 10 μL) in a short time (5 min) with a limit of detection for OTA equal to 1.3 ng/mL. The LoC has been applied for the detection of OTA (5-200 ng/mL) in beer and wheat samples.

Top-30

Citations by journals

1
2
3
Talanta
3 publications, 13.04%
Sensors and Actuators, B: Chemical
2 publications, 8.7%
IEEE Sensors Journal
1 publication, 4.35%
Materials
1 publication, 4.35%
Biocell
1 publication, 4.35%
Biosensors
1 publication, 4.35%
Trends in Food Science and Technology
1 publication, 4.35%
Journal of Hazardous Materials
1 publication, 4.35%
Bioelectrochemistry
1 publication, 4.35%
Sensing and Bio-Sensing Research
1 publication, 4.35%
Food Chemistry
1 publication, 4.35%
Journal of Electroanalytical Chemistry
1 publication, 4.35%
ACS Food Science & Technology
1 publication, 4.35%
IEEE Transactions on Electron Devices
1 publication, 4.35%
World Mycotoxin Journal
1 publication, 4.35%
Journal of Food Science and Technology
1 publication, 4.35%
Polymers for Advanced Technologies
1 publication, 4.35%
Russian Chemical Reviews
1 publication, 4.35%
Analytical Chemistry
1 publication, 4.35%
1
2
3

Citations by publishers

2
4
6
8
10
12
Elsevier
11 publications, 47.83%
IEEE
2 publications, 8.7%
Multidisciplinary Digital Publishing Institute (MDPI)
2 publications, 8.7%
American Chemical Society (ACS)
2 publications, 8.7%
Tech Science Press
1 publication, 4.35%
Wageningen Academic Publishers
1 publication, 4.35%
Springer Nature
1 publication, 4.35%
Wiley
1 publication, 4.35%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 4.35%
2
4
6
8
10
12
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
Share
Cite this
GOST |
Cite this
GOST Copy
Costantini F. et al. Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat // ACS Applied Bio Materials. 2019. Vol. 2. No. 12. pp. 5880-5887.
GOST all authors (up to 50) Copy
Costantini F., Lovecchio N., Ruggi A., Manetti C., Nascetti A., Reverberi M., de Cesare G., Caputo D. Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat // ACS Applied Bio Materials. 2019. Vol. 2. No. 12. pp. 5880-5887.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1021/acsabm.9b00831
UR - https://doi.org/10.1021/acsabm.9b00831
TI - Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat
T2 - ACS Applied Bio Materials
AU - Lovecchio, Nicola
AU - Ruggi, Albert
AU - Manetti, Cesare
AU - Nascetti, Augusto
AU - Reverberi, Massimo
AU - Caputo, Domenico
AU - Costantini, Francesca
AU - de Cesare, Giampiero
PY - 2019
DA - 2019/11/07 00:00:00
PB - American Chemical Society (ACS)
SP - 5880-5887
IS - 12
VL - 2
SN - 2576-6422
SN - 2576-6422
ER -
BibTex |
Cite this
BibTex Copy
@article{2019_Costantini,
author = {Nicola Lovecchio and Albert Ruggi and Cesare Manetti and Augusto Nascetti and Massimo Reverberi and Domenico Caputo and Francesca Costantini and Giampiero de Cesare},
title = {Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat},
journal = {ACS Applied Bio Materials},
year = {2019},
volume = {2},
publisher = {American Chemical Society (ACS)},
month = {nov},
url = {https://doi.org/10.1021/acsabm.9b00831},
number = {12},
pages = {5880--5887},
doi = {10.1021/acsabm.9b00831}
}
MLA
Cite this
MLA Copy
Costantini, Francesca, et al. “Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat.” ACS Applied Bio Materials, vol. 2, no. 12, Nov. 2019, pp. 5880-5887. https://doi.org/10.1021/acsabm.9b00831.
Found error?