This paper reports on the development of a fluorescent label-free aptamer assay integrated in a lab-on-chip (LoC) system for the detection of Ochratoxin A (OTA). The detection system relies on the integration, on a single glass substrate, of an array of amorphous silicon photosensors and a long pass interferential filter. The aptamer assay, integrated into the microfluidic network, is an aptasensor having affinity versus OTA, selected as a case study. The fluorescent molecule is a "light switch" complex [Ru(phen)2(dppz)]2+. The aptamer is directly anchored into a layer of poly(2-hydroxyethyl methacrylate) polymer brushes grown inside the channels. The fluorophore is intercalated between the base pairs of the aptamer. Upon the interaction of OTA with the aptasensor, a change of the aptamer conformation causes the release of the fluorophore, yielding a decrease of the fluorescent signal detected by the array of the amorphous silicon photosensors positioned underneath the microfluidic network. The developed LoC is a portable system capable of performing the analysis with a small volume of sample (about 10 μL) in a short time (5 min) with a limit of detection for OTA equal to 1.3 ng/mL. The LoC has been applied for the detection of OTA (5-200 ng/mL) in beer and wheat samples.
Для доступа к списку цитирований публикации необходимо авторизоваться.
Для доступа к списку профилей, цитирующих публикацию, необходимо авторизоваться.

Топ-30

Журналы

1
2
3
Talanta
3 публикации, 10.34%
Sensors and Actuators, B: Chemical
2 публикации, 6.9%
Microchemical Journal
2 публикации, 6.9%
IEEE Sensors Journal
1 публикация, 3.45%
Materials
1 публикация, 3.45%
Biocell
1 публикация, 3.45%
Biosensors
1 публикация, 3.45%
Trends in Food Science and Technology
1 публикация, 3.45%
Journal of Hazardous Materials
1 публикация, 3.45%
Bioelectrochemistry
1 публикация, 3.45%
Sensing and Bio-Sensing Research
1 публикация, 3.45%
Food Chemistry
1 публикация, 3.45%
Journal of Electroanalytical Chemistry
1 публикация, 3.45%
ACS Food Science & Technology
1 публикация, 3.45%
IEEE Transactions on Electron Devices
1 публикация, 3.45%
World Mycotoxin Journal
1 публикация, 3.45%
Journal of Food Science and Technology
1 публикация, 3.45%
Polymers for Advanced Technologies
1 публикация, 3.45%
Russian Chemical Reviews
1 публикация, 3.45%
Analytical Chemistry
1 публикация, 3.45%
Lab on a Chip
1 публикация, 3.45%
Plants
1 публикация, 3.45%
ACS Sensors
1 публикация, 3.45%
1
2
3

Издатели

2
4
6
8
10
12
14
Elsevier
14 публикаций, 48.28%
MDPI
3 публикации, 10.34%
American Chemical Society (ACS)
3 публикации, 10.34%
Institute of Electrical and Electronics Engineers (IEEE)
2 публикации, 6.9%
Tech Science Press
1 публикация, 3.45%
Wageningen Academic Publishers
1 публикация, 3.45%
Springer Nature
1 публикация, 3.45%
Wiley
1 публикация, 3.45%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 3.45%
SPIE-Intl Soc Optical Eng
1 публикация, 3.45%
Royal Society of Chemistry (RSC)
1 публикация, 3.45%
2
4
6
8
10
12
14
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
29
Поделиться
Цитировать
ГОСТ |
Цитировать
Costantini F. et al. Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat // ACS Applied Bio Materials. 2019. Vol. 2. No. 12. pp. 5880-5887.
ГОСТ со всеми авторами (до 50) Скопировать
Costantini F., Lovecchio N., Ruggi A., Manetti C., Nascetti A., Reverberi M., de Cesare G., Caputo D. Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat // ACS Applied Bio Materials. 2019. Vol. 2. No. 12. pp. 5880-5887.
RIS |
Цитировать
TY - JOUR
DO - 10.1021/acsabm.9b00831
UR - https://doi.org/10.1021/acsabm.9b00831
TI - Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat
T2 - ACS Applied Bio Materials
AU - Costantini, Francesca
AU - Lovecchio, Nicola
AU - Ruggi, Albert
AU - Manetti, Cesare
AU - Nascetti, Augusto
AU - Reverberi, Massimo
AU - de Cesare, Giampiero
AU - Caputo, Domenico
PY - 2019
DA - 2019/11/07
PB - American Chemical Society (ACS)
SP - 5880-5887
IS - 12
VL - 2
PMID - 35021509
SN - 2576-6422
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2019_Costantini,
author = {Francesca Costantini and Nicola Lovecchio and Albert Ruggi and Cesare Manetti and Augusto Nascetti and Massimo Reverberi and Giampiero de Cesare and Domenico Caputo},
title = {Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat},
journal = {ACS Applied Bio Materials},
year = {2019},
volume = {2},
publisher = {American Chemical Society (ACS)},
month = {nov},
url = {https://doi.org/10.1021/acsabm.9b00831},
number = {12},
pages = {5880--5887},
doi = {10.1021/acsabm.9b00831}
}
MLA
Цитировать
Costantini, Francesca, et al. “Fluorescent Label-Free Aptasensor Integrated in a Lab-on-Chip System for the Detection of Ochratoxin A in Beer and Wheat.” ACS Applied Bio Materials, vol. 2, no. 12, Nov. 2019, pp. 5880-5887. https://doi.org/10.1021/acsabm.9b00831.
Ошибка в публикации?