Abstract
There is currently no well-defined procedure for providing the limit of detection (LOD) in multivariate calibration. Defining an estimator for the LOD in this scenario has shown to be more complex than intuitively extending the traditional univariate definition. For these reasons, although many attempts have been made to arrive at a reasonable convention, additional effort is required to achieve full agreement between the univariate and multivariate LOD definitions. In this work, a novel approach is presented to estimate the LOD in partial least-squares (PLS) calibration. Instead of a single LOD value, an interval of LODs is provided, which depends on the variation of the background composition in the calibration space. This is in contrast with previously proposed univariate extensions of the LOD concept. With the present definition, the LOD interval becomes a parameter characterizing the overall PLS calibration model, and not each test sample in particular, as has been proposed in the past. The new approach takes into account IUPAC official recommendations, and also the latest developments in error-in-variables theory for PLS calibration. Both simulated and real analytical systems have been studied for illustrating the properties of the new LOD concept.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
5
10
15
20
25
|
|
|
Talanta
24 publications, 7.43%
|
|
|
Microchemical Journal
20 publications, 6.19%
|
|
|
Food Chemistry
13 publications, 4.02%
|
|
|
Spectrochimica Acta, Part B: Atomic Spectroscopy
13 publications, 4.02%
|
|
|
Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
12 publications, 3.72%
|
|
|
Analytical Methods
11 publications, 3.41%
|
|
|
Analytical Chemistry
9 publications, 2.79%
|
|
|
Chemometrics and Intelligent Laboratory Systems
9 publications, 2.79%
|
|
|
Analytica Chimica Acta
9 publications, 2.79%
|
|
|
Sensors
8 publications, 2.48%
|
|
|
Sensors and Actuators, B: Chemical
8 publications, 2.48%
|
|
|
Applied Spectroscopy
6 publications, 1.86%
|
|
|
Molecules
6 publications, 1.86%
|
|
|
Journal of Food Composition and Analysis
6 publications, 1.86%
|
|
|
Journal of Pharmaceutical and Biomedical Analysis
6 publications, 1.86%
|
|
|
The Analyst
5 publications, 1.55%
|
|
|
Food Control
4 publications, 1.24%
|
|
|
Journal of Analytical Atomic Spectrometry
4 publications, 1.24%
|
|
|
Proceedings of SPIE - The International Society for Optical Engineering
4 publications, 1.24%
|
|
|
Biosensors
3 publications, 0.93%
|
|
|
Foods
3 publications, 0.93%
|
|
|
Analytical and Bioanalytical Chemistry
3 publications, 0.93%
|
|
|
LWT - Food Science and Technology
3 publications, 0.93%
|
|
|
ACS Omega
3 publications, 0.93%
|
|
|
Journal of Dairy Science
3 publications, 0.93%
|
|
|
Data Handling in Science and Technology
3 publications, 0.93%
|
|
|
Planta Medica
3 publications, 0.93%
|
|
|
International Dairy Journal
2 publications, 0.62%
|
|
|
Journal of Chromatography A
2 publications, 0.62%
|
|
|
5
10
15
20
25
|
Publishers
|
20
40
60
80
100
120
140
160
180
|
|
|
Elsevier
178 publications, 55.11%
|
|
|
Royal Society of Chemistry (RSC)
27 publications, 8.36%
|
|
|
American Chemical Society (ACS)
26 publications, 8.05%
|
|
|
MDPI
24 publications, 7.43%
|
|
|
Wiley
18 publications, 5.57%
|
|
|
Springer Nature
13 publications, 4.02%
|
|
|
SAGE
8 publications, 2.48%
|
|
|
SPIE-Intl Soc Optical Eng
4 publications, 1.24%
|
|
|
Taylor & Francis
4 publications, 1.24%
|
|
|
Optica Publishing Group
3 publications, 0.93%
|
|
|
Georg Thieme Verlag KG
3 publications, 0.93%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
2 publications, 0.62%
|
|
|
Cold Spring Harbor Laboratory
2 publications, 0.62%
|
|
|
Mary Ann Liebert
1 publication, 0.31%
|
|
|
Frontiers Media S.A.
1 publication, 0.31%
|
|
|
IOP Publishing
1 publication, 0.31%
|
|
|
Public Library of Science (PLoS)
1 publication, 0.31%
|
|
|
Hrvatsko Farmaceutsko Drustvo/Croatian Pharmaceutical Society
1 publication, 0.31%
|
|
|
Hindawi Limited
1 publication, 0.31%
|
|
|
Pleiades Publishing
1 publication, 0.31%
|
|
|
20
40
60
80
100
120
140
160
180
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
323
Total citations:
323
Citations from 2024:
88
(27%)
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Allegrini F., Olivieri A. C. IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration // Analytical Chemistry. 2014. Vol. 86. No. 15. pp. 7858-7866.
GOST all authors (up to 50)
Copy
Allegrini F., Olivieri A. C. IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration // Analytical Chemistry. 2014. Vol. 86. No. 15. pp. 7858-7866.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1021/ac501786u
UR - https://doi.org/10.1021/ac501786u
TI - IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration
T2 - Analytical Chemistry
AU - Allegrini, Franco
AU - Olivieri, Alejandro C.
PY - 2014
DA - 2014/07/17
PB - American Chemical Society (ACS)
SP - 7858-7866
IS - 15
VL - 86
PMID - 25008998
SN - 0003-2700
SN - 1520-6882
SN - 2154-2686
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2014_Allegrini,
author = {Franco Allegrini and Alejandro C. Olivieri},
title = {IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration},
journal = {Analytical Chemistry},
year = {2014},
volume = {86},
publisher = {American Chemical Society (ACS)},
month = {jul},
url = {https://doi.org/10.1021/ac501786u},
number = {15},
pages = {7858--7866},
doi = {10.1021/ac501786u}
}
Cite this
MLA
Copy
Allegrini, Franco, and Alejandro C. Olivieri. “IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration.” Analytical Chemistry, vol. 86, no. 15, Jul. 2014, pp. 7858-7866. https://doi.org/10.1021/ac501786u.